Josef Lechleitner, Alexandros Andralis, Ardeshir Mahdavi

Abstract: This paper deals with the accuracy of simulation models in room acoustics. Acoustical measurements were conducted in five existing lecture halls in a university. The measured parameters included reverberation time, sound level distribution, and STI (sound transmission index). Parallel to the measurements, the same parameters were computed using a detailed room acoustics simulation program. Measurements and simulation results were compared toward an objective evaluation of the simulation model's accuracy. Comparison results showed a good agreement between measured and simulated reverberation times and sound pressure levels. KURZFASSUNG Dieser Beitrag beschäftigt sich mit der Genauigkeit raumakustischer Simulation. Zu diesem Zweck wurden in 5 bestehenden Räumen (Hörsälen) raumakustische Messungen durchgeführt. Dabei wurden Parameter wie Nachhallzeit, Schallpegelverteilung und STI gemessen. Parallel wurden dieselben Parameter mittels eines detaillierten raumakustischen Simulationsprogrammes ermittelt. Durch den Vergleich der gemessenen und berechneten Werte der raumakustischen Indikatoren, war es möglich, die Genauigkeit der Simulationsergebnisse zu beurteilen. Die Gegenübereinstellung von Messung und Simulation zeigte eine gute Übereinstimmung der gemessenen und simulierten Nachhallzeiten und Schallpegelverteilungen.