Conference Paper

Proceedings of Building Simulation 2019: 16th Conference of IBPSA

     

Hygro-Thermal Implications Of The Aerogel-Based Façade Insulation Layer Position And Thickness

Samira Aien 1, Ardeshir Mahdavi 2
1 TU Wien, Austria
2 TU Wien, Austria


DOI: https://doi.org/10.26868/25222708.2019.210711
Abstract: Application of insulation to existing facades can improve buildings' energy performance and reduce condensation risk. However, in case of historical buildings, the preservation of the façade's appearance represents a constraint regarding the choice of insulation method. In such cases, aerogel-based plaster may provide a solution. In this context, the present study investigated the effect of aerogel plaster position and thickness on the hygro-thermal performance of residential buildings using a simulation model. The results suggest that, with regard to the surface condensation risk, the position of aerogel plaster (outside versus inside) – but not so much its thickness – significantly influences the risk of condensation.
Keywords: Retrofit, hygro-thermal, Monitored data, Calibration, Insulation thickness, Aerogel plaster
Pages: 389 - 394
Paper: